Showing posts with label Space heaters. Show all posts
Showing posts with label Space heaters. Show all posts

Tuesday, March 17, 2015

West Seattle Knob and Tube Rewire

This particular rewire stemmed from another Angies List Customer calling in to get his 1920's Knob and Tube wiring looked at. The home is located in West Seattle. The process for the home inspection begins with taking off all of the wall plates. Most Electrical contractors will only use a plug checker to determine the extent of the knob and tube, not Seatown Electric. Our process is very thorough and accurate, leaving all of our customers with a detailed report of how much of the home is knob and tube, and what condition it is in. We have a 24hr turnaround process for all of our estimates, so the bid process does not drag out.





After a few back and forth e-mails confirming scope of work and misc. additional items, the homeowner let us know that we where the middle bid. Our price for the rewire was not too high and not too low. We scheduled the work for 5 total working days.

The house was vacant during the rewire (this is not required) but does help. There are many different Wiring Methods, but after many rewires, we believe we have found the best most efficient way to do them. On day one, we focus on pulling out all of the old switches and outlets. We aren't concerned with keeping the old outlets since they aren't Tamper Resistant which is required in the 2014 NEC Code. Not every single outlet is required to be Tamper Resistant, but enough for Seatown Electric to make it a company policy that all outlets will be Tamper Resistant.


Once the outlets and switches are removed, the next step is to remove all of the old metal boxes. This home had lath and plaster, so we had to be very careful not to knock out pieces of the wall. Using a flat head screw driver we disassemble and pry out the old boxes. Then cut out the opening for the new Plastic Cut In Box. After all the new boxes are cut out, we vacuum up all of the lath and plaster pieces and shake off the drop clothes in the trash, to get ready for the next steps.

Getting all of the boxes out and removing the knob and tube will take up most of day one. On day two, home run wires are pulled. Home runs are the start of the new circuit. Basically, they come from
the electrical panel to the start of the circuit. Once they are all pulled in, we start fishing wires in to all of the new electrical box locations. NMB Wiring is used for all of the new electrical installed. The next few days we are fishing in the new circuits.

 Seattle Electrical Code only requires you to rewire the dwelling "as is" meaning you only need to rewire to the existing locations. Labor and Industries will sometimes make you rewire "up to NEC Code" meaning you have to add outlets and switches. This adds a minimum of 3-5 days. Since the home was in Seattle territory, we only added outlets that the homeowner requested.

On the last day of the rewire the circuits are all attached to the Electrical panel. This homeowner chose to purchase the best Electrical Panel we offer. It comes with a copper bussing, whole home surge protection, updated grounding and bonding, panel labeling, and limited lifetime warranty on all parts.

A thorough testing of all the circuits is done after power is restored to the home. Everything worked perfect the first time. Inspection was scheduled the next day, and passed off the first time. This whole home rewire went about as smooth as it could have. Another satisfied Angies List customer.




Sunday, March 15, 2015

Safety Hazards With Space Heaters in Seattle Washington

We thought some helpful information would be good on electrical space heaters, And some of the dangers that come with plugging them into lighting circuits. Most homeowners would not think twice to plug there new space heater into any old outlet. Seatown Electric has had countless service calls in the Seattle area over outlets that are burned up or breakers that are tripped due to overloaded circuits.

Most older homes have overloaded circuits just from being wired "to code". Because back when the wiring was done, it was done in an era where only a few appliances were used. With technology changing rapidly, there is defiantly a need for more power.

So how much is a typical 15 amp circuit rated for? Household devices are required to run at 110-125 volts and most are rated at 115 volts so 1725 watts for a 15 amp cord or circuit. It is generally considered to be a good idea to not run at the exact rating of the breaker or fuse using this voltage because the voltage can rise, increasing the amps, Not to mention the fuses or breakers will sometimes fail. 80% is a number commonly suggested, in this case it is easier to just to suggest 1500 watts which is about 13 amps.

So what happens if you plug in a space heater? It depends on the wattage of the heater, you can check this on the manufacture label. Most can be found as a sticker mounted on the side. A typical space heater runs at roughly 1200-1800 watts. What this means is by plugging in the space heater you have come close, if not already maxed out the breakers max load.

In Seattle, Knob and Tube is present in roughly 30% of homes. The wiring method was to support a table lamp in each room and maybe a couple small appliances in the kitchen. Most of these homes have the entire upper floor on one circuit. If you plug a space heater into any Seattle home with knob and tube wiring, You are most likely putting the home into serious risk, Especially if the home has an outdated electrical panel. Then you have no overcurrent protection if you do in fact overload the circuit with a space heater.

There is a couple steps you can take to prevent electrical fires, or burned outlets from space heaters. The first step is map out the homes electrical system. Seatown Electric in Seattle Washington is one of many Seattle Electrical Contractors to choose from when hiring to resolve electrical issues. Going through the house and get a detailed label and map of what each circuit is doing helps to determine how the original wiring was done. Step two, Is to have a look at the electrical fuse panel or breaker box. If it has been updated within the last 20 years then AFCI Breakers would be recommended to help catch any faults in the circuits or appliances that are plugged in. If the panel box is older than 20 years it is recommended that it be upgraded. If Knob and Tube is present, an estimate to get it removed would be recommended.

By this time you should have a pretty good idea of how the electrical is wired, your Electrical Contractor most likely can come up with recommendations on the next steps to accommodate your space heaters. They will include fixes such as, dedicated circuits, splitting up existing overloaded circuits, installing AFCI or GFCI beakers, New panel box, and Rewiring old Knob and Tube.
Above is an image of an outlet found by Seatown Electric on a service call in Seattle Washington, The homeowner had smelled burning in there newborns nursery. There was an 1800 watt heater plugged in, the entire floor including the kitchen was on one circuit. There was no breakers in the home, just old screw in fuses. The home had no ground, No smoke detectors with Knob and Tube wiring, and was asking for a fire. Luckily the homeowner called when they did, because as you can see this outlet was about to create a fire with no warning.

To sum up this post, think twice before plugging in one or multiple space heaters. If you are not sure of the condition of your homes electrical you owe it to yourself and your family to have an Electrical Contractor look it over. And please, bare minimum get interconnected smoke detectors installed to at least warn your family of a potential fire.

For scheduling a free estimate in the Seattle area please visit www.seatownelectric.com